{"id":7107,"date":"2024-11-11T10:40:34","date_gmt":"2024-11-11T01:40:34","guid":{"rendered":"https:\/\/hoyats.cr8ive.fun\/products\/product_details\/hts-twins%ef%bc%92plate-system\/"},"modified":"2025-11-18T16:20:26","modified_gmt":"2025-11-18T07:20:26","slug":"hts-twins%ef%bc%92plate-system","status":"publish","type":"medical_products","link":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/","title":{"rendered":"HTS Twins 2"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<p>HTS Twins 2 provides (realizes or assures) sturdy angle and rotational stability for femoral neck fractures. <br>A wide range of size options are available for various cases.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Variable size options<\/strong><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Width of distances between the upper screw and the lower screw are available in two options: 18.6 mm (regular size) and 21.0 mm (wide size), and the four sizes of barrel lengths are available corresponding to the screw length.<\/li>\n\n\n\n<li>Two screw length options, 110 mm , and 120 mm length screws, are available for the 130\u00b0 plates, which are loaded with more weight-bearing force.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"624\" height=\"655\" src=\"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/twins_pic01.jpg\" alt=\"\" class=\"wp-image-5522\" style=\"width:372px;height:auto\"\/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Anti-rotation locking mechanism<\/strong><\/h4>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"624\" height=\"400\" src=\"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/twins_pic02.jpg\" alt=\"\" class=\"wp-image-5524\"\/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">Clinical Result<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Displacement Analysis<\/strong><\/h4>\n\n\n\n<p>The analysis of the implant displacement, which simulated femoral neck fractures, was measured by the FEM test. The result shows the mitigation of implant displacement amount compared to the previous products as shown in the graph. <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"318\" src=\"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/twins_pic03.jpg\" alt=\"\" class=\"wp-image-5526\" style=\"width:816px;height:auto\"\/><\/figure>\n<\/div>\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Features HTS Twins 2 provides (realizes or assures) sturdy angle and rotational stability for femoral neck fractures. A wide range of size options are available for various cases. Variable size options Anti-rotation locking mechanism Clinical Result Displacement Analysis The analysis of the implant displacement, which simulated femoral neck fractures, was measured by the FEM test. The result shows the mitigation of implant displacement amount compared to the previous products as shown in the graph.<\/p>\n","protected":false},"author":6,"featured_media":5512,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","footnotes":""},"category_medical_products":[42],"feature_medical_products":[],"part_medical_products":[125],"class_list":["post-7107","medical_products","type-medical_products","status-publish","format-standard","has-post-thumbnail","hentry","category_medical_products-bone_joint","part_medical_products-femur-cervical-en"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HTS Twins 2 | Products for medical professionals | Product Information | HOYA Technosurgical Corporation<\/title>\n<meta name=\"description\" content=\"HTS Twins2 is a compression hip screw for femoral neck fractures. It provides strong angular and rotational stability for femoral neck fractures. A variety of sizes are available to meet the needs of different patients.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HTS Twins 2 | Products for medical professionals | Product Information | HOYA Technosurgical Corporation\" \/>\n<meta property=\"og:description\" content=\"HTS Twins2 is a compression hip screw for femoral neck fractures. It provides strong angular and rotational stability for femoral neck fractures. A variety of sizes are available to meet the needs of different patients.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/\" \/>\n<meta property=\"og:site_name\" content=\"HOYA Technosurgical\u682a\u5f0f\u4f1a\u793e\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-18T07:20:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/Twins2_img.png\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"240\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/\",\"url\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/\",\"name\":\"HTS Twins 2 | Products for medical professionals | Product Information | HOYA Technosurgical Corporation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/wp\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Twins2_img.png\",\"datePublished\":\"2024-11-11T01:40:34+00:00\",\"dateModified\":\"2025-11-18T07:20:26+00:00\",\"description\":\"HTS Twins2 is a compression hip screw for femoral neck fractures. It provides strong angular and rotational stability for femoral neck fractures. A variety of sizes are available to meet the needs of different patients.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/wp\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Twins2_img.png\",\"contentUrl\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/wp\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Twins2_img.png\",\"width\":300,\"height\":240},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/hts-twins%ef%bc%92plate-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u30db\u30fc\u30e0\",\"item\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u533b\u7642\u95a2\u4fc2\u8005\u5411\u3051\u88fd\u54c1\",\"item\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/products\\\/product_details\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HTS Twins 2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/\",\"name\":\"HOYA Technosurgical\u682a\u5f0f\u4f1a\u793e\",\"description\":\"HOYA Technosurgical\u682a\u5f0f\u4f1a\u793e\u306f\u3001\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u88fd\u30a4\u30f3\u30d7\u30e9\u30f3\u30c8\u3001\u91d1\u5c5e\u88fd\u30a4\u30f3\u30d7\u30e9\u30f3\u30c8\u306e\u88fd\u9020\u30fb\u8ca9\u58f2\u3092\u901a\u3058\u3001\u6574\u5f62\u5916\u79d1\u9818\u57df\u3067\u3088\u308a\u512a\u308c\u305f\u88fd\u54c1\u3092\u63d0\u4f9b\u3057\u3066\u3044\u304f\u3068\u5171\u306b\u3001\u8133\u795e\u7d4c\u5916\u79d1\u3001\u5f62\u6210\u5916\u79d1\u3001\u6b6f\u79d1\u9818\u57df\u306b\u304a\u304d\u307e\u3057\u3066\u3082\u3055\u3089\u306a\u308b\u533b\u7642\u8ca2\u732e\u3092\u76ee\u6307\u3057\u3066\u9081\u9032\u3057\u3066\u307e\u3044\u308a\u307e\u3059\u3002\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.hoyatechnosurgical.co.jp\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HTS Twins 2 | Products for medical professionals | Product Information | HOYA Technosurgical Corporation","description":"HTS Twins2 is a compression hip screw for femoral neck fractures. It provides strong angular and rotational stability for femoral neck fractures. A variety of sizes are available to meet the needs of different patients.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/","og_locale":"en_US","og_type":"article","og_title":"HTS Twins 2 | Products for medical professionals | Product Information | HOYA Technosurgical Corporation","og_description":"HTS Twins2 is a compression hip screw for femoral neck fractures. It provides strong angular and rotational stability for femoral neck fractures. A variety of sizes are available to meet the needs of different patients.","og_url":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/","og_site_name":"HOYA Technosurgical\u682a\u5f0f\u4f1a\u793e","article_modified_time":"2025-11-18T07:20:26+00:00","og_image":[{"width":300,"height":240,"url":"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/Twins2_img.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/","url":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/","name":"HTS Twins 2 | Products for medical professionals | Product Information | HOYA Technosurgical Corporation","isPartOf":{"@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/#primaryimage"},"image":{"@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/Twins2_img.png","datePublished":"2024-11-11T01:40:34+00:00","dateModified":"2025-11-18T07:20:26+00:00","description":"HTS Twins2 is a compression hip screw for femoral neck fractures. It provides strong angular and rotational stability for femoral neck fractures. A variety of sizes are available to meet the needs of different patients.","breadcrumb":{"@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/#primaryimage","url":"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/Twins2_img.png","contentUrl":"https:\/\/www.hoyatechnosurgical.co.jp\/wp\/wp-content\/uploads\/2024\/11\/Twins2_img.png","width":300,"height":240},{"@type":"BreadcrumbList","@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/hts-twins%ef%bc%92plate-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u30db\u30fc\u30e0","item":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/"},{"@type":"ListItem","position":2,"name":"\u533b\u7642\u95a2\u4fc2\u8005\u5411\u3051\u88fd\u54c1","item":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/products\/product_details\/"},{"@type":"ListItem","position":3,"name":"HTS Twins 2"}]},{"@type":"WebSite","@id":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/#website","url":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/","name":"HOYA Technosurgical\u682a\u5f0f\u4f1a\u793e","description":"HOYA Technosurgical\u682a\u5f0f\u4f1a\u793e\u306f\u3001\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u88fd\u30a4\u30f3\u30d7\u30e9\u30f3\u30c8\u3001\u91d1\u5c5e\u88fd\u30a4\u30f3\u30d7\u30e9\u30f3\u30c8\u306e\u88fd\u9020\u30fb\u8ca9\u58f2\u3092\u901a\u3058\u3001\u6574\u5f62\u5916\u79d1\u9818\u57df\u3067\u3088\u308a\u512a\u308c\u305f\u88fd\u54c1\u3092\u63d0\u4f9b\u3057\u3066\u3044\u304f\u3068\u5171\u306b\u3001\u8133\u795e\u7d4c\u5916\u79d1\u3001\u5f62\u6210\u5916\u79d1\u3001\u6b6f\u79d1\u9818\u57df\u306b\u304a\u304d\u307e\u3057\u3066\u3082\u3055\u3089\u306a\u308b\u533b\u7642\u8ca2\u732e\u3092\u76ee\u6307\u3057\u3066\u9081\u9032\u3057\u3066\u307e\u3044\u308a\u307e\u3059\u3002","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/medical_products\/7107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/medical_products"}],"about":[{"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/types\/medical_products"}],"author":[{"embeddable":true,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/comments?post=7107"}],"version-history":[{"count":7,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/medical_products\/7107\/revisions"}],"predecessor-version":[{"id":8930,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/medical_products\/7107\/revisions\/8930"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/media\/5512"}],"wp:attachment":[{"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/media?parent=7107"}],"wp:term":[{"taxonomy":"category_medical_products","embeddable":true,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/category_medical_products?post=7107"},{"taxonomy":"feature_medical_products","embeddable":true,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/feature_medical_products?post=7107"},{"taxonomy":"part_medical_products","embeddable":true,"href":"https:\/\/www.hoyatechnosurgical.co.jp\/en\/wp-json\/wp\/v2\/part_medical_products?post=7107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}